Office UPS, Protecting Computers from Power Outages
What a UPS does, which type to choose for an office, what to plug into it, how to size it and how to maintain it so it doesn't let you down.
Published 10 min read
A power cut lasting a few seconds seems like a minor thing: the lights flicker, the computers restart, everyone sighs. But if the server or NAS was writing to disk at that moment, you can lose files or even an entire database. A UPS (uninterruptible power supply) prevents exactly that. Below you’ll find how it works, which type suits you, how to size it and how to keep it in working order.
What a UPS actually does
A UPS sits between the wall socket and your equipment, with a battery inside. When mains power drops out or becomes unstable, the UPS switches to battery and the equipment keeps running.
The battery isn’t designed to keep the office going for hours. Its job is to cover short outages and give you time to shut equipment down properly during long ones. A UPS also protects against other problems on the electrical supply:
- brief voltage dips that restart computers;
- voltage that’s too low or too high for longer periods;
- voltage spikes, for example from lightning or when large equipment in the building starts up.
In an office, you see the effect in small things: the server no longer goes through long disk checks after every outage, the accounting software’s database doesn’t get corrupted, and the router stops restarting several times a day when the voltage fluctuates.
Types of UPS and how they differ
There are three main types on the market. The difference is how they handle power while the mains supply is working.
Offline (standby)
It lets mains power pass straight through to the equipment and switches to battery only when the power drops. It’s the simplest and cheapest type. It suits a single office computer or a router, where the electrical supply is generally good.
Line-interactive
On top of the battery, it corrects voltage that’s too low or too high by itself, without draining the battery. For most small offices it’s the balanced choice: it protects the server, NAS and network equipment without the cost of an online UPS.
Online (double conversion)
It converts the power all the time: from AC to DC, then back into clean AC. The equipment doesn’t notice the switch to battery at all. It’s used for important servers, or where the electrical supply is weak and unstable. It costs more, makes more noise and uses a little more electricity.
One detail to check on cheaper UPS units: the waveform on battery. Some produce an approximated wave, not a sine wave. Most equipment tolerates it for a short time, but some fussier server or computer power supplies don’t. The manufacturer’s specifications say which waveform the UPS produces.
Example: a small office with a NAS
Take an office with a router, a switch, a NAS and a computer running the accounting software. The router, switch and NAS usually draw little power, and a line-interactive office UPS keeps them running for a long time. The computer and monitor draw more and shorten the runtime.
A practical setup is one UPS for the network cabinet (router, switch, NAS) and a separate small one under the accountant’s desk. If one has a problem, the other stays up, and each is sized for what it has to carry.
What to plug into the UPS and what not to
The priority is simple: whatever would damage data or stop the whole office if it shut off suddenly.
Plug into the UPS:
- the server and the NAS, which are most exposed to data loss;
- the router, switch and Wi-Fi access points, so the network keeps working during short outages;
- computers used for important data, such as the accounting software;
- the phone system or IP phones, if the office needs to keep answering calls.
Don’t plug into the UPS:
- laser printers, which draw a lot of current when starting and warming up and can overload the UPS;
- heaters, coffee machines, fridges;
- extension leads full of other appliances, which add up load without you knowing how much.
Many UPS units have two kinds of sockets: some on battery and others with surge protection only. The printer can go on the latter.
How to size a UPS
UPS capacity is usually given in two units: VA (volt-amperes) and W (watts). The one that matters for your calculation is watts, because it tells you how much real load the unit can handle.
The practical steps:
- List the equipment you want to connect to the UPS.
- Find out what each item draws. It’s on the power supply label or in the data sheet. Bear in mind the label shows maximum consumption, not typical, so your calculation will include a safety margin.
- Add up the figures and choose a UPS whose rating in watts exceeds the total, with headroom. A UPS loaded close to its limit runs for less time on battery and gets hot.
- Check the runtime. Manufacturers publish tables or online calculators showing how long the battery lasts at a given load. You need enough time for the server and NAS to shut themselves down, not hours.
- Count the sockets and check their type. Some rack-mount UPS units have IEC outlets, not ordinary sockets.
If you have a network cabinet, there are rack-mount UPS units that sit next to the switch. For a small office, a floor-standing model placed next to the NAS is usually enough.
Automatic shutdown for the server and NAS
A UPS buys time, but that’s pointless if nothing shuts the equipment down before the battery runs out. That’s where the data connection between the UPS and your equipment comes in.
- Most UPS units have a USB port. You connect it to the NAS or server, which then reads the battery status.
- In the NAS settings (usually under power or “UPS”), choose how long it should run on battery before shutting itself down.
- On a Windows server, the UPS manufacturer provides software that does the same thing.
- Some NAS devices can also tell other equipment on the network to shut down, using the same UPS.
Test the setup: unplug the UPS from the wall on a quiet day and check that the NAS shuts down by itself at the time you set. Far better to find out now that it doesn’t work than during a real outage.
If you don’t have a NAS yet, our article on a NAS for a small office explains why its power supply matters so much.
Batteries wear out: UPS maintenance
UPS batteries don’t last forever. They wear with age, with heat and with every discharge. A UPS with a dead battery looks fine until the day the power drops and it shuts off along with everything else.
What to do:
- Keep the UPS somewhere cool and ventilated. Heat shortens battery life considerably. Don’t shut it in an unventilated cupboard next to a radiator.
- Leave the automatic self-test on. Many UPS units test their battery periodically and warn you with a beep or an LED.
- Pay attention to warnings. A repeated beep or a red “replace battery” light shouldn’t be ignored.
- Write down when the battery was fitted. Manufacturers give the expected battery life in their documentation; plan the replacement before it runs out.
- Replace the battery with the model the manufacturer specifies. Many UPS units let you swap the battery without powering down the equipment.
Old batteries don’t go in household waste. Take them to a collection point or back to the seller.
Where to put it and how to connect it
Where the UPS sits matters almost as much as the model. A few practical rules:
- Close to the equipment, so you don’t need long extension leads between the UPS and the NAS or server.
- Straight into the wall socket, not into an extension lead or another UPS. Two UPS units chained together don’t get along well.
- On a circuit without heavy loads. If the air conditioning or the office kitchen shares the same breaker, the UPS will switch to battery often and wear out faster.
- With easy access to the buttons and display, so you can see the warnings.
- With the data cable connected, USB or network, so it can alert the NAS and server.
Label the sockets: what’s on battery and what’s on surge protection only. A year from now, nobody will remember why a particular cable was plugged in there.
What to check after a power cut
After a longer outage, check a few things:
- The NAS and server have started by themselves and the data volumes are fine.
- The backup scheduled for that night has finished, or needs starting again.
- The UPS has recharged its battery and isn’t showing any warnings.
- The router has internet again and the VPN works for anyone working from home.
If a device doesn’t start by itself when power returns, check its settings (or the BIOS, on computers) for the option to power on automatically after power is restored.
Surge protector or UPS?
Extension leads “with surge protection” are useful, but they aren’t UPS units. They stop some voltage spikes, but when the power drops, the equipment still shuts off just as abruptly.
There’s also a third category: voltage stabilisers. They correct the voltage but have no battery, so they don’t help during outages. They’re used mainly where the building’s voltage is consistently too low or too high.
For ordinary office computers, where autosave reduces the risk to documents, a good surge-protected extension lead can be enough. For the server, NAS, router and switch, a UPS is the right choice.
Frequently asked questions
How long does a UPS last on battery?
It depends on the battery capacity and how much the connected equipment draws. A small UPS with just a router runs far longer than the same UPS with a server and a monitor. Manufacturers publish runtime tables for each model.
Can I plug my laptop into the UPS?
You can, but a laptop already has a battery and switches to it by itself. It’s more useful to connect the router and switch, so the laptop keeps internet and file access during a short outage.
Why is my UPS beeping?
Usually because it has switched to battery, because the battery needs replacing or because it’s overloaded. The manual explains what each signal means. A UPS that beeps when the power hasn’t dropped deserves a check straight away.
Which checks count as preventive maintenance for a UPS?
Battery tests, dust cleaning, checking the load and the battery replacement date. They’re typical examples of preventive maintenance, one of the types described in our answer on the four types of maintenance.
Does a UPS protect against lightning?
It protects against some voltage spikes, but it doesn’t guarantee protection from lightning striking the building or the line directly. In areas with frequent storms, an electrician can fit surge protection in the distribution board as a first barrier. Don’t forget the network cable or phone line either, which can also carry a spike in.
When to call a technician
If you have a server or NAS without a UPS, if your UPS has been beeping for months, or if you don’t know whether automatic shutdown works, a check is worthwhile. We choose the right model for your equipment, set up automatic shutdown and test it.
Power outage protection is part of the IT maintenance we do for businesses, alongside backup and your office network.